Skip to main content

Striking London Building Catches the Eye as well as the Sun with Kingspan Solar

One building in Central London is using solar thermal tubes not just to generate renewable energy but also to create a remarkable and eye-catching facade.



In marked contrast to more typically discrete installations of renewable energy technology, architect Nick Baker chose to celebrate the inclusion of solar collectors in his Camden development by placing them on the front of the building.


The striking five-storey residential building in Delancey Street features a commercial unit on the ground floor and 14 residential flats on the upper floors.  Sustainability is woven into the fabric, as well as the façade of the building, in order to achieve a Level 3 rating from The Code for Sustainable Homes.

In all, there are 925 Kingspan Solar Varisol solar thermal evacuated tube collectors which hang in banks down the front and outer walls of the building, creating a unique and beautiful frontage which sits comfortably within a designated Conservation area.

The specification for this new, and highly bespoke, renewable energy installation was done by Kingspan’s in-house designers and engineers.

A particular consideration was the design of the front of the building and the nature of the space to be used.  Where solar panels and tubes are typically laid on a flat surface, at Delancey Street the south/south-west side of the building is curved.

The first problem, the curvature, was overcome by placing the collector tubes within six vertical banks.  The second, and potentially more pressing concern, was the irregular space which each bank needed to exactly fill to complete the building’s unique façade.

Here, the adaptability of Varisol solar thermal collector tubes comes into its own.  They are custom-made to fill unequal or bespoke spaces through their clever modular design.  Normal manifold collectors hold a specific number (20 or 30) of tubes in rigid panels, making them highly inflexible.  But the number of Varisol collectors tubes can be varied to ensure that the installation exactly matches the size of the space to be filled.  They are also highly durable, making them an ideal choice to ‘put on display’.   Thus, in Delancey Street, the final facade incorporated four banks of 175 solar collector tubes, one bank with 133 tubes and one bank with 92 tubes.

And just to complete the look, the polymer ends of the tubes were encased in a smart metal cover, leaving just the glass collectors to catch the sun as well as eye.



The Kingspan Solar engineers also had to consider the secure fixing of the collector tubes to the building’s insulated front walls.

They liaised closely with their counterparts at Kingspan Insulated Panels who had supplied the high-spec Benchmark Karrier panels.  Drilling into the panels was not an option because of the irreparable damage it would have done, severely compromising the insulating performance.  Instead, specially developed brackets were designed by Kingspan engineers to secure the solar tubes, leaving the panels structurally unaffected.


Simon Bonfield, Kingspan’s Specification Manager, advises: “The precision with which our installers could place the Varisol tubes as an integral part of the building’s design was vital in this development.   The result is so striking it stops traffic in the area!

“But it’s not just beautiful, it’s also highly effective at capturing solar energy.  The scheme provides nearly 93 metres2 of solar thermal tubes in total, saving more than 5,000 metres3 of gas, lowering CO2 emissions by around 11,000kg.”  

The installation is eligible for the Non-Domestic Renewable Heat Incentive (RHI) payments, the Government scheme which provide financial subsidies for renewable heat technologies for the lifetime of the installation (20 years).

Payments are based on the amount of heat generated per kilowatt hour (kWth); solar installations such as Delancey Street will generate a guaranteed payment of 10p per kWth.

The development has been named ‘Solstice Point’- which is quite fitting as it was installed by Solstice Energy Ltd and its sister company Solstice Heat Ltd - with one of the inner courtyards called ‘The Solar Park’.

The same ethos of solar thermal functionality and design has also been used in other countries, including Lane Community College in the United States where Kingspan Solar Varisol evacuated collector tubes are arranged to provide shading in the summer to assist the passive cooling of the building while generating heat for hot water and giving privacy to the multiple floors of the lobby.

In Switzerland, 124 Varisol DF split into rows of 11 and 9 tubes were again sized exactly to fit within a limited area in a three-storey building and are completely integrated into the structural design – as the balcony balustrade.

Comments

Popular posts from this blog

The Beginners Guide to Pipe Insulation: Flexible Foams

Next up in the series we are doing on pipe insulation is "flexible foams"; a category that includes polyethylene and expanded nitrile rubber.


Polyethylene Pipe Insulation
Climaflex pipe insulation is the UK's leading brand for polyethylene pipe insulation. This is the grey foam that most people are familiar with, the kind you would traditionally find in garden centres for example. Polyethylene is the cheapest, widely available product in the market. People very often wrongly assume cheap means poor quality, this is not the case with a brand such as Climaflex. It has a thermal conductivity of 0.034 W/m.K at 0°C which is broadly equal to that of any other flexible foam, and it also has a much higher "μ factor" than other foams, making it more resistant to moisture ingress. These facotrs make it ideal for use around the home, being easy to work with and providing good insulation. 
The material can be purchased in 1m and 2m lengths, and is available in wall thicknesse…

The Beginners Guide To Pipe Insulation: Getting to grip with the basics

Our Beginners Guide series of blogs will look at the common areas of pipe insulation lagging that you will want to look at when choosing your product. This guide will be of most interest to the DIY installers, but some of our later guides will cover more complex products and areas of application.

One of the things we get asked about a lot is what the dimensions quoted for pipe insulation actually mean. You will always see three measurements quoted when describing pipe insulation; Wall Thickness, Bore Size and Length.

In the below diagram, A is the "Bore" and B is the "Wall".

Wall thickness is very simply how much insulation you have; so for example if you have 13mm Wall pipe insulation, then that means you have 13mm of insulation on either side of your pipe. This thickness is very often one of the most important part of your decision; too thin and you might not get the results you are looking for but too thick and it might not fit between your pipe and the wall.

If…

Frost protection for domestic pipes

With the cold weather approaching we thought it would be a good idea to touch on how best to protect your pipes from frost this winter.

When dealing with frost protection on pipes inside a building your aim with insulating them is to delay the onset of freezing for as long as possible; it is not possible to guarantee a pipe will not freeze by insulation alone. The better the insulation, and the thicker the insulation, the longer you will give yourself. Under normal circumstances you aim to give yourself about 8-10 hours protection against sub zero temperatures. With pipes inside a home this is usually long enough to be sure the pipes will not freeze.


Ice formation inside the pipes will lead to an increase in pressure. As the water tries to flow this pressure will increase, and eventually will lead to the pipes bursting. A burst pipe can cause a lot of problems, not least of which is a lot of damage to your property and a lot of expense incurred.

Water regulations state that all water …